Clinical and Laboratory Standards Institute (CLSI) EP15-A3 Calculations


[Up] [Top]

Documentation for package ‘CLSIEP15’ version 0.1.0

Help Pages

bias_validation_interval Calculate bias validation interval
calculate_aov_infos Calculate ANOVA Results and Imprecision Estimates
calculate_bias_interval Calculate bias interval from TV
calculate_dfWL Calculate degres of freedom within-lab as specified in appendix B
calculate_df_combined Calculate degrees of freedom of SE C (SE combined) given a selected scenario and additional parameters necessary for the scenario
calculate_F_uvl Calculate the UVL factor
calculate_m Calculate M
calculate_n0 Calculate n0
calculate_se_c Calculate SE combined based on SE X and SE RM
calculate_se_rm Calculate SE RM given a scenario and a list of additional args that can change based on the selected scenario or sub scenario
calculate_se_rm_a_lowerupper Calculate SE RM for scenario A when f the manufacturer supplies lower and upper limits and coverage confidence interval (95 or 99...)
calculate_se_rm_a_u Calculate SE RM for scenario A when <e2><80><9c>standard error<e2><80><9d> or <e2><80><9c>standard uncertainty<e2><80><9d> (abbreviated by lowercase <e2><80><9c>u<e2><80><9d>) or <e2><80><9c>combined standard uncertainty<e2><80><9d> (often denoted by <e2><80><9c>uC <e2><80><9d>)
calculate_se_rm_a_Ucoverage Calculate SE RM for scenario A when f the manufacturer supplies an <e2><80><9c>expanded uncertainty<e2><80><9d> (abbreviated by uppercase <e2><80><9c>U<e2><80><9d>) for the TV and coverage e.g. 95 or 99,
calculate_se_rm_a_Uk Calculate SE RM for scenario A when f the manufacturer supplies an <e2><80><9c>expanded uncertainty<e2><80><9d> (abbreviated by uppercase <e2><80><9c>U<e2><80><9d>) for the TV and the <e2><80><9c>coverage factor<e2><80><9d> (abbreviated by <e2><80><9c>k<e2><80><9d>)
calculate_se_rm_scenario_b_c Calculate SE RM for scenario B or C If the reference material has a TV determined by PT or peer group results
calculate_se_rm_scenario_d_e Calculate SE RM for scenario D or E If the TV represents a conventional quantity value or When working with a commercial QC material supplied with a TV for which the standard error cannot be estimated
calculate_se_x Calculate SE x
calculate_uvl_info Calculate upper verification limit
create_table_ep_15 Create table for precision calculations
dfc_references Reference of degrees of freedon based on tau given in the CLSI Manual
ferritin_long Ferrtin data used in CLSI document examples in wide format
ferritin_wider Ferrtin data used in CLSI document examples in wide format